MAINTENANCE AND LUBRICATION GRT9165 OPERATOR MANUAL
6-44 Published 7-23-2020, Control # 668-02
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Boom Lubrication (Continued)
60
Hook Block
Swivel Bearing
Figure 6-22 A
Until grease
extrudes
Every 250 hours, or
3 months of service,
whichever interval
comes first
LUBRICATE 1 to
2 service points
See NOTE 50.
See NOTE 51.
See NOTE 53.
61A
Hook Block
Sheaves 100MT
Figure 6-22
Every 250 hours, or
3 months of service,
whichever interval
comes first
CHECK sheaves on
each of five (5) hook
blocks listed.
1 service point ea
as defined below:
CHECK sheaves
for dry points of
operation
CHECK sheaves
for grease leaks
See NOTE 52.
61B
Hook Block
Sheaves 120MT
61C
Hook Block
Sheaves – 26MT
61D
Hook Block
Sheaves – 45MT
61E
Hook Block
Sheaves – 75MT
62 Swivel Rope
Figure 6-22 A
Until grease
extrudes
Every 250 hours, or
3 months of service,
whichever interval
comes first
LUBRICATE
1 service point on
each of three (3)
items listed
See NOTE 50.
See NOTE 51.
See NOTE 53.
63 Overhaul Weight
64 Overhaul Ball
NOTE 50: DO NOT USE non semi-synthetic lubricant. Use of non-approved lubricant may damage components.
NOTE 51: Before operating crane in cold weather (arctic) ambient temperatures below -9°C (+15°F), Standard grease
must be fully purged and replaced with Cold Weather grease meeting Grove U.S. L.L.C. specifications as
shown in Table 6-4: Approved Lubricant Reference Table, page 6-11 in this Operator Manual. See also your
GRT9165 Service Manual for maintenance and lubrication instructions.
NOTE 52: Slowly turn the sheave, and examine it for rough or dry points of operation and grease leaks. If rough or dry
points of operation are found, then replace the sheave. If grease leaks are found, then replace the sheave.
NOTE 53: If the weather is very bad or operating conditions are poor, then more frequent intervals are necessary. Monitor
the service points and adjust lubrication intervals, as necessary.
CAUTION
Possible Equipment Damage!
Use semi-synthetic or synthetic lubricants as listed in Section 6 of this Operator Manual. See
also your GRT9165 Service Manual for maintenance and lubrication instructions.
Use of non-approved, non semi-synthetic lubricant may damage components and/or
invalidate published lubricant intervals.
Failure to follow this instruction may cause damage to equipment.

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals