A-6 Published 7-23-2020, Control # 668-02
360Û SWING LOCK
DO NOT ENGAGE 360Û SWING LOCK WHILE SUPER-
STRUCTURE IS IN MOTION.
CAUTION
80117046
111
120
119
118
117
30
104
116
404
406
28
109
107
INSIDE COVER
INSIDE GLASS
IN CLEAR VIEW
OF OPERATOR
6
5
108
102
ON TOP
SURFACE
23
101
115
110
105
103
7
7
10
9
8
8
112
CAUTION
PIN SWING LOCK
Do not engage Pin Swing Lock while
superstructure is in motion. Center boom over
front and engage Pin Swing Lock to prevent
rotation during travel.
7376011340
UNLOCK
LOCK
PIN
SWI N G
LOCK
80026772G7
PULL
PUSH
80064053EN
PATENT INFORMATION:
https://ir.manitowoc.com/investor-
relations/resources/Intellectual-
Property
Be sure outriggers are properly extended and set and
crane is level for operation on outriggers.
All four outrigger beams must be equally extended to
the appropriate vertical stripe before beginning
operation.
All four outrigger beam lock pins must be engaged
before operating from the mid-extend position.
Operator must select proper load chart and RCL
program for the outrigger position selected.
7376007441
DANGER
ELECTROCUTION HAZARD
TO AVOID DEATH OR SERIOUS INJURY
Keep ALL parts of the crane, rigging and load at
least 20 feet (6 meters) away from any energized
power line. You MUST follow the OSHA require-
ments set forth in 29CFR 1926.1407 through
1926.1411.
This crane is not designed or equipped for use
within 10 feet (3 meters) of energized power lines
[Refer to 29CFR1926.1410 Table A]. If operation
within 10 feet (3 meters) or any power lines cannot
be avoided, the power utility MUST be notified and
the power lines MUST be de-energized and
grounded BEFORE performing any work.
If contact is ever accidentally made with a power
line and any part of this crane, its rigging or load,
NEVER touch the crane or even approach or come
near the crane.
Electrocution CAN OCCUR even without direct
contact with the crane.
G7 80041097
G7
80034750
CAUTION
TRANSMISSION DAMAGE
To prevent transmission damage: shift
between 2-wheel and 4-wheel drive only
with crane stopped and transmission in
neutral and service brake applied.
7376100080G7
CRUSHING HAZARD
DEATH OR SERIOUS INJURY COULD RESULT
FROM BEING CRUSHED BY MOVING
MACHINERY.
Before actuating swing or any other function,
sound horn and verify that all personnel are
clear of rotating and moving parts.
DANGER
80036656
TELESCOPE BOOM OUT
TELESCOPE BOOM IN
BOOM UP
BOOM DOWN
REAR WHEELS
NOT CENTERED
IGNITION "ON" AND/
OR VOLTMETER
ENGINE RPM
HORN
ENGINE TEMPERATURE
DRIVE LIGHTS
PARK LIGHTS
ENGINE STOP
MODULE MALFUNCTION
LOW FUEL LEVEL
TRANSMISSION
WARNING
ELECT SYSTEM
DIAGNOSTIC
P
BOOM LIGHTS
WASHER
WORK LIGHTS
WIPER SKYLIGHT
SWING BOOM RIGHT
SWING BOOM LEFT
WAIT TO START
2 WHEEL DRIVE
4 WHEEL DRIVE
CAB HEATER
DISABLE REGENERATION
OUTRIGGER JACK
OUTRIGGER BEAM
OUTRIGGER EXTEND
OUTRIGGER RETRACT
REAR STEER
TURNING RIGHT
REAR STEER
TURNING LEFT
AUXILIARY HOIST DOWN
ENGINE DECREASE
ENGINE INCREASE
AIR CONDITION
AUXILIARY HOIST UP
SWING BRAKE RELEASE
SWING BRAKE ENGAGED
MAIN HOIST DOWN
MAIN HOIST UP
DIFFERENTIAL LOCKED
PARK BRAKE RELEASE
PARK BRAKE ENGAGED
FAST
SLOW
HAZARDS
ENGINE DIAGNOSTICS
P
P
CRANE FUNCTION
POWER ON
CRANE FUNCTION
POWER OFF
3
3 WRAPS ON HOIST
DISENGAGED/OFF
LAMP MALFUNCTION
LOW STEER
PRESSURE
LOW BRAKE
PRESSURE
HYDRAULIC
OIL HIGH TEMP
DIESEL PARTICULATE FILTER
EMERGENCY STOP
DIESEL EXHAUST FLUID
HIGH EXHAUST
TEMPERATURE
STOP
ENGINE WARNING
STOP
CAB TILT UP
CAB TILT DOWN
LUFFING EXTENSION
AUTO
MAN
BOOM OUT OF SYNC
BOOM CENTER MID
BOOM INNER MID
A
A MODE
B
B MODE
MANUAL MODE
AUTO MODE
G7
F1 - UE + Cab SCMO/IOL32 Module Battery Power
F2 - UE + T/T CCM10/IOL45/ IOS20 Module Battery Power
F3 - RADIO / CRANESTAR BATTERY POWER
F4 - E-STOP SW SIG
F5 - KEY SW SIG
F6 - SYS WAKE-UP
F7 - OIL COOLER POWER FAN 2
F8 - UB+ T/T 10L45 POWER
F9 - UB+ T/T 10L45 POWER
F10 - OIL COOLER POWER FAN 1
F11 - ACTUATOR 1, 2, & 3 RELAY FUSE POWER
F12 - DISPLAY / JOGDIAL RELAY FUSE POWER
F13 - DIAGNOSTIC CONN POWER
F14 - ACC LIGHTS
F15 - HEATER / AC SW POWER
F16 - CIRC FAN
F17 - MAP LT & USB POWER
F18 - SYS WAKE-UP
F19 - HEATED SEAT POWER
F20 - WINDSHIELD WASHER RELAY FUSE POWER
F21 - WINDSHIELD WIPER POWER
F22 - UB+ T/T CCM10
F23 - UB+ T/T CCM10
F24 - CAB WORK LIGHTS
F25 - UB + IOL32
F26 - UB + IOL32
F27 - B+ TO KEY SW
F28 - DOME LIGHT
F29 - FUSE B+
F30 - 24V SUPPLY
F33 - SKY LT WASHER RELAY FUSE POWER
F34 - SKY LT WIPER
F35 - BOOM MOTORIZED WORKLIGHTS
K01 - ACC RELAY
K02 - ACT ENABLE RELAY
K03 - SKY LT WIPER
K04 - DISPLAY / JOGDIAL RELAY
K05 - ACT 1 (IN) RELAY
K06 - ACT 1 (OUT) RELAY
K07 - HORN RELAY
K08 - SKY LT WIPER HIGH
K09 - SKY LT WIPER LOW
K10 - ACT 2 (IN) RELAY
K11 - ACT 2 (OUT) RELAY
K12 - ACT 3 (IN) RELAY
K13 - ACT 3 (OUT) RELAY
K14 - SKY LT WASHER RELAY
K15 - WINDSHIELD WIPER RELAY
K16 - WINDSHIELD WIPER RELAY
K17 - WINDSHIELD WIPER RELAY
K18 - WINDSHIELD WASHER RELAY
X1 - BATTERY DISC SW POWER WIRE 5
X2 - BATTERY DISC SW POWER WIRE 6
X3 - BATTERY DISC SW POWER WIRE1274
X4 - GROUND
F29
F4
F35
F14
F17
F18
F23
F22
F30
F32
F13
F25
F11
F25
F11
F2
F3
F1
F10
F7
F8
F9
F16
F15
F28
F34
F21
F33
K18
K3 K9
A
B
C
K1
K16
K15 K8
K14
K17
K10 K6 K12
K11 K5
K2
X1 X2 X3
K4
K7
D5
K13
F6
F5
F20
F19
F24
F26
X4
D1
D2
D4 D3
CAB FUSE AND RELAY BOARD
80116984G7
5
5
3
3
5
10
15
10
20
15
15
20
15
10
5
10
3
5
15
15
15
15
5
15
5
5
10
10
19
10
1
25
18
9
9
18
25
1
10
19
19
10
1
25
18
9
10
5
5
5
5
10
EMERGENCY EXIT
IN EMERGENCY,
PUSH OUT WINDOW
AND ESCAPE
THROUGH OPENING.
7376009502
CAB WITH STEERING COLUMN AND SEAT REMOVED
CAB SECTION VIEW
CAB OUTSIDE REAR VIEWBEHIND CAB SEAT
SINGLE AXIS DUAL AXIS
NO STEP
7376007370
SEAT BACK MUST BE IN FULL UPRIGHT
POSITION AND LEFT ARMREST MUST BE
ROTATED BACK TO NON-OPERATIONAL
POSITION BEFORE ENTERING OR
LEAVING CAB.
7376009507
CAUTION
1
1
G7 80117002
2
2
G7 80077416
80117009
MODEL
SERIAL
Grove U.S. L.L.C.
P.O. BOX 21, SHADY GROVE, PA 17256, U.S.A.
7679100089
MFG. DATE
MODEL YR.
26
DANGER
7376102946
To avoid death or serious injury:
Never mix gasoline, alcohol, or gasohol
with diesel fuel. This mixture can cause
an explosion.
G7
Use only ultra low sulfur fuel. Failure to
do so may cause damage to the catalyst.
80101847 C5
FIGURE A-1 continued
10031

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals