EasyManua.ls Logo

Marport Catch Sensor - Page 85

Marport Catch Sensor
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Catch Sensors | V1 | Servicing and Maintenance
2.
Remove the retainer ring around the transducer (yellow part).
3.
To remove the black tube around the bottle, place the bottle in a vise or on the ground
and pull out the black tube.
You have now access to the electronic components.
4.
Remove the tape protecting the components.
5.
Disconnect the battery from the PCBA and remove the battery.
6.
Carefully disconnect the up (B), uplink (C) and uplink LED cable from the PCBA using
needle nose pliers.
7.
Remove the two screws maintaining the transducer with the 1/8" Allen key.
8.
Remove the transducer and its cables.
| 85