EasyManuals Logo

METREL EurotestXE User Manual

METREL EurotestXE
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
MI 3102(H) BT EurotestXE Technical specifications
91
10.4 RCD testing
10.4.1 General data
Nominal residual current (A, AC) ............ 10 mA, 30 mA, 100 mA, 300 mA, 500 mA,
1000 mA
Nominal residual current (EV, MI) ........... 30 mA a.c., 6 mA d.c.
Nominal residual current accuracy .......... -0 / +0.1I; I = IN, 2IN, 5IN
-0.1I / +0; I = 0.5IN
AS/NZS selected: ± 5 %
Test current shape .................................. Sine-wave (AC), pulsed (A, F), smooth DC (B, B+)
DC offset for pulsed test current ............. 6 mA (typical)
RCD type ................................................ (non-delayed), S (time-delayed), PRCD, PRCD-K,
PRCD-S, EV RCD, MI RCD
Test current starting polarity .................. 0º or 180º
Voltage range ......................................... 93 V 134 V (45 Hz 65 Hz)
185 V 266 V (45 Hz 65 Hz)
I
N
× 1/2
(mA)
I
N
× 1
(mA)
I
N
× 2
(mA)
I
N
× 5
(mA)
RCD I
I
N
(mA)
AC
A, F
B, B+
AC
A, F
B, B+
AC
A, F
B, B+
AC
A, F
B, B+
AC
A, F
B, B+
10
5
3.5
5
10
20
20
20
40
40
50
100
100
30
15
10.5
15
30
42
60
60
84
120
150
212
300
100
50
35
50
100
141
200
200
282
400
500
707
1000
300
150
105
150
300
424
600
600
848
n.a.
1500
n.a.
n.a.
500
250
175
250
500
707
1000
1000
1410
n.a.
2500
n.a.
n.a.
1000
500
350
500
1000
1410
n.a.
2000
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a. ......................................................... not applicable
............................................................. applicable
AC type................................................... sine wave test current
A, F types…… ........................................ pulsed current
B, B+ types ............................................. smooth DC current (MI 3102 BT only)
IN × 1/2
(mA)
IN × 1
(mA)
IN × 2
(mA)
IN × 5
(mA)
RCD I
IN (mA)
EV / MI a.c
EV / MI a.c
EV / MI a.c
EV / MI a.c
EV / MI a.c.
EV / MI d.c.
30 a.c.
15
30
60
150
n.a
6 d.c.
n.a
n.a
n.a
n.a
n.a
n.a. ......................................................... not applicable
............................................................. applicable
EV, MI type (a.c. part). ........................... sine wave test current
EV, MI type (d.c. part) ............................. smooth DC current

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the METREL EurotestXE and is the answer not in the manual?

METREL EurotestXE Specifications

General IconGeneral
BrandMETREL
ModelEurotestXE
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals