28 – Control CS 310 / Rev.I 1.55
Function Description Setting options Factory settings
FORE-
WARNING
The forewarning is activated before an automatic closing run starts and before closing
in impulse mode.
Please note: This time is added to the start warning.
OFF,
1 – 300 seconds
OFF
AUT.CLOSE Automatic closing after the open time has elapsed.
MOD1: AUT.CLOSE from OPEN end position
MOD2: AUT.CLOSE from end position Part OPEN
MOD3: AUT.CLOSE from OPEN end position and Part OPEN end position
MOD4: AUT.CLOSE from all door/gate positions
MOD1 – MOD4 MOD1
FAST CL. Earlier closing after the photocell has been driven past.
Requirements:
A photocell must be installed at passage height and an open time greater than 0
must have been programmed.
With open time = 0 the door closes directly after passing through the light barrier.
MOD2: The open time is cut short after the photocell (door closes immediately).
If the photocell is driven through during an opening run, the programmed
open time is ignored and the door closes immediately.
MOD3: The open time is cut short after the photocell beam has been interrupted
foraminimumof2seconds(inordertodiscountpedestriantrafc).
If the photocell is driven through during an opening run, the programmed
open time is ignored and the door closes immediately.
MOD4: As for MOD2, except that the photocell has no function during the
opening run.
OFF,
MOD2 – MOD4
OFF
RELAY 1 A relay mode from 1 – 13, 17 – 19, 21 – 46 and 60 – 62 can be assigned to all four
relays.
Relay 4 can also be programmed with MOD14 – 16.
Further explanations:
“10.3Explanationoftherelaymodes:“onpage34
MOD1: (Redtrafclight1inside)ashesduringforewarningandisONduring
door run*
MOD2: (Redtrafclight2inside)ashesduringforewarningandduringdoorrun*
MOD3: (Redtrafclight3inside)isONduringforewarningandduringdoorrun*
MOD4: Impulse signal when OPEN command is given from inside
MOD5: Error message
MOD6: OPEN end position
MOD7: CLOSED end position
MOD8: OPEN end position negated
MOD9: CLOSED end position negated
MOD10: Intermediate position OPEN
MOD11: Intermediate position CLOSE
MOD12: Intermediate position CLOSE to CLOSED end position
MOD13: Magnetic lock function
MOD14: Brake (normally energised mode)
MOD15: Brake (normally de-energised mode)
MOD16: Brake (normally energised mode) switched on in OPEN end position
MOD17: SKS activated or test error
MOD18: (Redtrafclight4inside)ashesduringforewarningandisOFFduring
door run
MOD19: Before-end position OPEN to OPEN end position
MOD21: Test of draw-in protection before opening run (additional module required)
MOD22: Activation of radio transmission systems 1 and 3 and/or light curtain
testing (NO)
MOD23:
(Greentrafclightinside)isONatOPENendposition,OFFduringforewar-
ning and OFF during door run*
MOD24: Capacitor switching for 230 V/1~ sectional-door operators
MOD25: Yard light function, light stays on for 2 minutes after OPEN impulse/
command
MOD26: Activation of radio 2 transmission system
MOD27: Impulse signal when OPEN end position is reached
MOD1 – MOD13
MOD17 – MOD19
MOD21 – MOD46
MOD60 – MOD62
MOD6
RELAY 2 MOD1 – MOD13
MOD17 – MOD19
MOD21 – MOD46
MOD60 – MOD62
MOD7
RELAY 3 MOD1 – MOD13
MOD17 – MOD19
MOD21 – MOD46
MOD60 – MOD62
MOD1
RELAY 4 MOD1 – MOD19
MOD21 – MOD46
MOD60 – MOD62
MOD14
Overview of functions