Appendix | Factory Settings
thermoMETER CT
Model CT-SF02/15/22/
CTF/CTH
CTM-1SF40 CTM-
1SF75
CTM-1SF75H1 CTM-
2SF40
CTM-
2SF75
Lower limit temperature range [°C] 0 485 650 800 250 385
Upper limit temperature range [°C] 500 1050 1800 2200 800 1600
Lower alarm limit [°C]
(normally closed)
30 600 800 1200 350 500
Upper alarm limit [°C]
(normally open)
100 900 1400 1600 600 1200
Model CTM-2SF75H1 CTM-3SF22 CTM-3SF33 CTM-3SF75H1
Lower limit temperature range [°C] 490 50 100 150
Upper limit temperature range [°C] 2000 400 600 1000
Lower alarm limit [°C]
(normally closed)
800 100 250 350
Upper alarm limit [°C]
(normally open)
1400 300 500 600
Model CTM-3SF75H2 CTM-3SF75H3 CTP-7 CTP-3
Lower limit temperature range [°C] 200 250 0 50
Upper limit temperature range [°C] 1500 1800 710 400
Lower alarm limit [°C]
(normally closed)
550 750 30 200
Upper alarm limit [°C]
(normally open)
1000 1200 100 300
Smart Averaging means a dynamic average adaptation at high signal edges (activation via CompactConnect software only), see A 5.