6.7 Program change (PRG)
Using this function you can make the Matrix send out Program Change commands to all
your expanders when you change Matrix Programs. A separate program number can be given to
every MIDI channel of every output of the Matrix.
This function works on outputs only.
This function works on outputs only.This function works on outputs only.
This function works on outputs only.
$
Call up the Program Change Mapping function:
»
PRG
«
.
In the top right of the display you will see the number and name of the current MIDI output.
LEDs light on the number keys representing outputs which already have settings.
$
Select an output using
to .
Change
Ch 1
“ to the MIDI channel on which you wish to send a Program Change
command.
Press
.
Using
!
, select the program number you wish to send whenever this Matrix Program is
selected.
If you press
, the command will be sent, so that you can check the effect on your
expander.
If necessary, move the blinking cursor with
across the two parameters and
program any other settings you need.
The “
Read
“ function allows you to check the settings of the current output.
The “
CLR
“ function allows you to delete the currently displayed Program Change.
%
Quit this function by pressing
.
Using “
BNK
“ you can define additional a Bank Select (Controller 0 and 32) to the currently
Program Change. The values for Controller 0 and 32 are together the required bank number, but
they are programed seperately. For the correct values please refer the manual of your sound device.
$
Select
»
BNK
«
.
Using
, you can move the blinking cursor across the two parameters.
Using
!
, you can change the values.
The “
Read
“ function allows you to check the settings without changing them
&
Using the “
Read
“ function Program Change values, handled with the Bank Select, will be
displayed completely. For all others, only the PC value will be shown.
Program Change: 1:
1
2 3 4 5 6 7 8
Program Change: Ch 1 1:
TMR CLR BNK Read
Program Change: Ch 1 1:
TMR CLR BNK Ctrl.0: 0 Ctrl.32: 0 Read