EasyManua.ls Logo

Milnor E-P Express - Chart 1: Restore Standard Formulas (Part A)

Milnor E-P Express
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Pellerin Milnor Corporation
CAUTION:
Avoid Data Loss Other than the two methods described above, it is not
possible to selectively delete field-modified or field-programmed formulas
with this programming mode. This mode erases all field-programmed for-
mulas 1 through 10 or 1 through 30 as specified. For selective deletions
and modifications, use Program mode 1 (Add/Change Formula).
CAUTION: Avoid Chemical Damanage to Goods The injection time for Chemical
1 is 30 seconds for all default formulas. This may prevent certain supply
systems from properly detecting which formula is running, or cause the in-
jection time for chemical 1 to be longer than intended.
Always verify the Chemical 1 injection time for each formula after re-
storing the standard formulas
2.3.5.1 Chart 1: Restore Standard Formulas (Part A)
BNCJUP02.T01 0000191350 A.4 A.8 A.6 1/2/20 1:16 PM Released
1. Start
2. Restore standard formulas?
This procedure replaces field-modified wash formulas with the standard formulas provided
by Milnor
®
.
YES: Continue to step 3
NO: Skip to 1.: step 1, Part C, page 35
3. Enable Program menu
Turn the Run/Program keyswitch to set the controller to the Program mode.
4. Select and Enable Standard Formulas
Scroll to Standard Formulas (item 3 of the Program Menu), then confirm the selection.
5. Clear formulas 11 - 30?
Do you want to keep or clear formulas 11 through 30?
YES: Continue to step 6
NO: Skip to 1.: step 1, Part B, page 35
6. Select and Confirm Default 30 Formulas
Continue with this procedure to replace formulas 1 through 10 with the standard formulas and
erase formulas 11 through 30.
7. Standard formulas written to memory
The controller will pause for a few seconds while the standard formulas are written to the con-
troller memory.
8. Return to Run mode
When the display becomes active again, turn the Run/Program keyswitch to the Run
position.
Programming

Table of Contents

Other manuals for Milnor E-P Express