Pellerin Milnor Corporation 39
CAUTION:
Ensure Data Integrity Clear the memory storage device before saving
data to it.
The memory storage device will hold all programming and configura-
tion data for one machine, and can be re-used many times. However, this
device will only accept new data when it's empty.
Attempts to save data to a storage device that has not been cleared will
fail, even if the procedure appears successful.
Display or Action Explanation
RUN PROGRAM00 OK TO
POWER OFF
When the Run Program display appears, switch from Run mode
to Program mode.
Turn the Run/Program keyswitch on the machine controller(s)
from the Run position to the Program position.
PROGRAM 0 MENU OK
TURN KEY TO RUN
Controller display when the Run/Program keyswitch is set to
(Program position).
Scroll down in the Program menu to Data Transfer. If two ma-
chines are connected together, this is required at both machines.
PROGRAM 4 MENU
DATA TRANSFER
This is the Data Transfer menu selection. Follow the procedure
in Section 2.3.6.2 : Saving Data from the Machine to the Storage
Device or a Second Machine, page 39 for making a copy of good
data from the machine controller. Refer to Section 2.3.6.3 : Re-
storing Saved Data to the Machine from the Storage Device or
Another Machine, page 41 for instructions on restoring previously
saved data from the storage device (or another machine) to the
machine controller, as might be required after changing the pro-
cessor board.
2.3.6.2 Saving Data from the Machine to the Storage Device or a
Second Machine
BNCJUP05.R02 0000195354 A.4 A.8 A.6 1/2/20 1:16 PM Released
Display or Action Explanation
Confirms selection and advances to the Data Transfer menu.
DOWN LOAD DEVICES0
MACHINE<==>MACHINE
This is the Data Download sub-menu. Select the desired type of
data transfer here.
DATA TRANSFER0
SLAVE
There are two selections available in the Data Transfer menu: 0=
Slave and 1=Master.
For saving information to the data storage device or another ma-
chine, select 1=Master at the machine controller. If two machines
are connected, establish the one which will receive the data as the
slave, and the sending machine as the master.
DATA TRANSFER1
MASTER
The machine controller is set as the Master device, making the
storage device the slave.
Programming

Table of Contents

Other manuals for Milnor E-P Express

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Milnor E-P Express and is the answer not in the manual?

Milnor E-P Express Specifications

General IconGeneral
BrandMilnor
ModelE-P Express
CategoryControl Unit
LanguageEnglish

Related product manuals