How to Set Cutting Conditions
3-15
Error messages related to the cutting conditions
The followings are error messages and the causes that will be displayed when setting cutting condi-
tions and changing to the remote mode. To solve them, see each reference page.
When the flat detection switch is ON or AUTO
When the flat detection switch is OFF
Error Message Cause
1.The cutter is too short.
2. Cutting is too deep.
P. 5-4
1.The flatness correction amount is not set when the flat
detection switch is ON or AUTO.
P. 5-4
1.The cutter is too long.
2.Flatness correction amount is too small
P. 5-4
1.The chip removal attachment is not set when the flat
detection switch is ON or AUTO.
2.When setting flat correction amount and A axis reference
point, dust-collecting nozzle is not attached.
P. 5-4
Error Message Cause
The flatness correction amount is set when the flat detec-
tion switch is OFF.
P. 5-5
When the flatness detection switch is "off" and the dust-col-
lecting nozzle is attached, the cutting is set to more than
4mm.
P. 5-5
[Remote] 1KB
Warning.1 Cut ter
t oo sho r t o r en -
grav i ng t oo deep
*Warning.2 *
Flatness correc-
t i on no t se t .
Pl ease set .
*Warning.3 *
Flatness correc-
t i on no t enough
Pl ease check !
*Warning.4 *
Set Chip removal
at tachment .
*Warning.5 *
Flatness sensor
sw i t ch i s OFF .
Tu r n i t on .
*Warning.6 *
Remove ch i p re-
mo v a l a t t a c hme n t

Table of Contents