How to Set Communication Conditions
4-9
How to Set Communication Conditions
Specify the communication conditions for RS-232C interface.
ā*ā indicates the default value.
1
Press (or ) to display
the third page of the local mode.
2
Press (or ) to display
the screen shown on the right.
3
Press (or ) to select
RS-232C.
Press the function key to set the values of BAUD
RATE, DATA BITS, and PARITY.
4
Press to go to the next page.
Press the function key to set the values of STOP BITS
and HANDSHAKE.
To return to the previous page, press .
5
Press to fix the setting.
*1
Item Indications on LCD Description
Baud Rate 1200 1200 bps
2400 2400 bps
4800 4800 bps
9600* 9600 bps
19200 19200 bps
Data Bits 7 7 bits
8* 8 bits
Parity NON* Parity check is not performed.
EVEN Even parity
ODD Odd parity
Stop Bits 1* 1 bit
1.5 1.5 bits
22 bits
Handshake HARD* Hardware handshake
CODE XON/XOFF handshake
*1. Press on the step 4 to cancel the setting.