4-4
Relation between overwriting of received data and copying
When the machine receives a new data from the host more than 10 seconds after finishing engraving
the last data, the data in the receive buffer of this machine is erased and replaced with a new one. If
copying after engraving the new data, only the new data is copied.
When the machine receives a new data from the host within 10 seconds after engraving the data A, the
new data is stored next in the data A.
When copied after engraving the data B, the machine engraves both the data A and the data B.
*1
*1. If a G-code is set using an operation switch command, because the local mode arises after engraving, the
data is replaced with new data even before 10 seconds elapse.