5-4
Other Error Messages
Cause Cutting data exceeds the effective cutting area.
Solution Enlarge the effective cutting area.
( P.3-7)
REMOTE
LOCAL
Cause1 The cutter is too short.
Solu-
tion1
Replace with a long cutter.
Cause2 Cutting depth is too deep.
Solu-
tion2
Reduce the cutting depth.
To cut deeply, set the flat detection switch to OFF.
( P.4-7)
Cause Flatness correction amount is not set when the auto flat
detection is ON or AUTO.
Solution Set the flat correction amount ( P.3-10) or set FLAT-
NESS to OFF( P.4-7).
Cause The cutter is too long.
Solution Flatness correction amount cannot be
set when “a” is 9 mm or more.
Replace it with a short cutter.
Cause The chip removal attachment is not mounted when the auto
flat detection is ON or AUTO.
Solution Mount the chip removal attachment ( P.1-11) or set
FLATNESS to OFF ( P.4-7).
Cause Flatness correction amount has been set when the flat
detection switch is OFF.
Solution Set Z axis reference point ( P.3-8) or set the flatness
correction amount with the flat detection switch ON or
AUTO. ( P.3-10)