Error Messages and Solutions
5-3
ERROR 461
MOTOR Z
An excessive load was applied to
the Z motor.
Turn the power off once and turn
it on again.
If the same error message still
appears, contact your distributor
or a sales office of MIMAKI.
ERROR 463
Z CURRENT
An overcurrent error in the motor in
the Z motor.
ERROR 510
X ORIGIN
The plotter has failed to detect the
origin sensor.
ERROR 50A
Y ORIGIN
ERROR 511
Z ORIGIN
ERR C80
ZM COMM.
ERROR C80
ZM Com.offscale
Stop send data.
then push CE key
The coordinate specified by 3-axis
line interpolation command (ZM) is
in off-scale area.
1. Change the parameter of ZM
command not to be placed in
off-scale area.
2. Reset the XY origin point and
Z axis reference point not to
be placed in off-scale area.
ERROR CA0
G-code offscale
ERROR CA0
G-code offscale
Stop send data,
then push CE key
The point specified by G-code data
went off the scale.
1. Check the G-code data.
2. Set the position of the work
coordinates origin to a
position in which it does not
go off the scale.
Error message Cause
Solution