3-11
1
2
3
4
5
6
Chapter 3 Setup
Setting Auto Cleaning
You can set the machine so that it counts the number of
printed files or the length or time after printing has been
completed, and performs cleaning automatically if required.
You can select the auto cleaning setting from three types
below:
PAGE : Set the cleaning intervals by the number of
printed files.
LENGTH : Set the cleaning intervals by the printed
length.
TIME : Set the cleaning intervals by the printed
time.
Besides, automatic nozzle check after auto cleaning can
be set. (Cleaning Check function)
The machine can perform a stable printing operation with
its heads always kept clean.
1
Press
(MENU)
in LOCAL.
2
Press to select SETUP 1 to 4,
and press the key.
SETUP MENU will be displayed.
3
Press
(>>)
twice.
4
Press to select “AUTO
CLEANING”, and press the key.
5
Press the key, and press
to select the type of auto cleaning.
There are “PAGE”, “LENGTH” and “TIME” for
auto cleaning.
FILE: When the set number of prints has been
completed, the machine performs
head cleaning automatically.
LENGTH:When the set length has passed, the
machine performs head cleaning
automatically.
TIME: When the set time has passed, the
machine performs head cleaning
automatically.
If you do not set auto cleaning, first select “OFF”
and then proceed to the Step 6.
6
Press , and press to
select the cleaning interval.
Depending on the auto cleaning type selected in
the Step 3, the setting value differs.
For FILE: 1 to 1000 file
For LENGTH:0.1 to 100.0m (in 0.1m increment)
For TIME: 10 to 120min (in 10min increment)
7
Press the key, and press
to select the cleaning type.
Set Value : NORMAL/ SOFT/HARD
8
Press the key, and press
to select “Cleaning Check”.
9
Press the key, and press
to select set value.
Set Value : ON/ OFF
10
Press the key .
11
Press the key several times to
end the setting.
Setting Interval wiping
When the set time has passed, nozzle face of the head is
cleaned automatically to remove ink droplets on the
nozzle face.
In case that deflection, nozzle missing, or symptom which
ink droplets fall down occurred, set the interval between
each operation shorter.
1
Press
(MENU)
in LOCAL.
2
Press to select SETUP 1 to 4,
and press the key.
SETUP MENU will be displayed.
3
Press
(>>)
twice.
4
Press to select “INTERVAL
WIPING”, and press the key.
5
Press to set intervals.
Set Value : 3 to 255 Minutes, OFF
When [OFF] is set, periodical wiping is not
executed.
6
Press the key.
7
Press the key several times to
end the setting.
Depending on the state of the heads, etc., the image
quality deterioration may not be improved even with
this function performed.In this case, contact our
service office or the distributor in your region.