EasyManua.ls Logo

MIMAKI TS300P-1800 - Reset the Set Value; Check the Condition for Which Nozzle Recovery Cannot be Performed; Enabling or Disabling Nozzle Recovery During a Test Print

MIMAKI TS300P-1800
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-14
Chapter 4 Maintenance
Reset the set value
1
Press
(MENU)
in LOCAL.
MAINTENANCE MENU will be displayed.
2
Press to select “NOZZLE
RECOVERY”, and press the key.
3
Press to select “RESET”, and
press the key.
4
Press and
(PAGE>)
(<<)
to selet the Nozzle line that
need reset, and press the key.
A reset confirmation message will be displayed.
5
Press the key.
6
Press the key several times to
end the setting.
Check the condition for which nozzle
recovery cannot be performed
1
Press
(MENU)
in LOCAL.
MAINTENANCE MENU will be displayed.
2
Press to select “NOZZLE
RECOVERY”, and press the key.
3
Press to select “CHECK”, and
press the key.
Judgement Condition input screen will be
displayed.
4
Adapt each item of the judgment
conditions to your current state.
(1) Press [][] to select the setting item,
and press the [ENTER] key.
(2) Press [][] to select the setting value,
and press the [ENTER] key.
(3) Repeat steps (1) and (2), and set all of the
items.
5
Press .
Begin to check if nozzle recovery at the set
printing conditions can be done.
When the check is completed, the judgment result
is displayed on the screen.
6
Press several times to end
the setting.
Enabling or disabling nozzle recov-
ery during a test print
To enable the nozzle recovery function during a test print
( P.2-16) , turn the following settings “ON”, and
register the numbers of the nozzles for recovery in “
Nozzle
Recovery Function
” on P.4-13.
1
Press
(MENU)
in LOCAL.
MAINTENANCE MENU will be displayed.
2
Press to select “NOZZLE
RECOVERY”, and press the key.
3
Press to select “TEST PRINT”,
and press the key.
4
Press to selet ON/OFF, and
press the key.
5
Press the key several times to
end.
Judgement Condition
Resolution
720 x 720
8
PASS
NORMAL
Scan Speed
>
MAPS 4
1
OVER PRINT
Judgement result
Judgement result
OK
If the nozzle
recovery
possible
HEAD1-AB
1
HEAD1-CD
0
HEAD2-AB
0
HEAD2-CD
2
NG
HEAD3-AB
1
HEAD3-CD
0
HEAD4-AB
0
HEAD4-CD
0
Judgement result
Judgement result
Judgement result
If the nozzle
recovery is not
possible
Head no. and
nozzle line
The number of
nozzles that can
not be recovered.

Table of Contents