4-11
1
2
2
4
5
6
Chapter 4 Maintenance
8
Close the front cover and press the
key.
9
Fill up the cap with cleaning solution for
maintenance
If the cleaning solution cartridge is usable,
maintenance solution is automatically filled.
When the cap is filled with cleaning solution, the
display will prompt you to check the cleaning
solution.
10
If a message is displayed, open the front
cover and check the amount of cleaning
solution in the cap.
11
Close the front cover, and press the
key.
12
Press to set the time for the
cleaning solution to be left as it is.
Set Value:1 to 99 min (by the unit of 1 min)
13
Press the key.
The nozzles are washed.
When the nozzles have been completely washed,
the head moves to the maintenance position.
14
Fill up the cap with cleaning solution for
maintenance
If the cleaning solution cartridge is usable,
maintenance solution is automatically filled.
15
If a END message is displayed, open the
front cover and check the amount of
cleaning solution in the cap.
16
Close the front cover and press the
key.
After its initial operation, the machine returns to
step2.
If the front cover is not closed, the cleaning
solution will not be automatically filled. If the front
cover is open, be sure to close it.
If the cleaning cartridge is not valid, the cleaning
solution will not be automatically filled to the cap.
Open the front cover and use a dropper to fill the
maintenance cleaning solution in the cap to just
before it overflows.
Once the cleaning solution is full, begin from Step 11.
If the solution does not fill up the cap, use a
dropper to fill the maintenance cleaning solution in
the cap to just before it overflows.
If the front cover is not closed, the cleaning
solution will not be automatically filled. If the front
cover is open, be sure to close it.
If the cleaning cartridge is not valid, the cleaning
solution will not be automatically filled to the cap.
Open the front cover and use a dropper to fill the
maintenance cleaning solution in the cap to just
before it overflows.
Once the cleaning solution is full, begin from Step 16.
If the solution does not fill up the cap, use a
dropper to fill the maintenance cleaning solution in
the cap to just before it overflows.