4-29
4
2
Chapter 4 Maintenance
10
When the correction processing is finished
successfully, remove all the weights on the
dish of the balance and press the
key.
• Perform the correction processing without the
weight on the balance.
11
When the correction processing is finished
successfully, set the ink tank that was
removed in step 8 and press the
key.
Correct by the correction method
“Adjust Zero Pos.”
1
Press the
(MENU)
in LOCAL.
2
Press to select “Maintenance”,
and press the key.
3
Press the
(>>)
.
4
Press to select “Tank
Calibration”, and press the key.
5
Press to select “Adjust Zero
Pos.” and press the key.
6
Press to select an ink tank (Slot 1
to 8) to be corrected, and press the
key.
7
Remove the ink tank of the selected slot
and press the key.
• Perform the correction processing without the
weight on the balance.
8
When the correction processing is finished
successfully, set the ink tank that was
removed in step 7 and press the
key.
• During the correction process, please do not give
vibration to the external ink supply unit. There is a
possibility to fail the correction process.
• When the correction process fails, “Failed” will be
shown on the display. Press the [ENTER] or
[END] key to clear the error display and press
again the [ENTER] key. It will resume the
correction processing.
• During the correction process, please do not give
vibration to the external ink supply unit. There is a
possibility to fail the correction process.
• When the correction process fails, “Failed” will be
shown on the display. Press the [ENTER] or
[END] key to clear the error display and press
again the [ENTER] key. It will resume the
correction processing.