4-4
Chapter 4 Maintenance
Cleaning the Area
around Flushing Unit
In order to prevent ink clogging of the head, this machine
ejects ink regularly to flushing unit.
To comfortably use this machine, please keep clean the
peripheral of flushing unit.
Cleaning the Flusing BOX Sensor
Please clean flushing BOX sensor regularly (about once a
week).
1
Remove the lower part of the left side front
cover.
(1) Remove the screws (for two positions) of the
lower part of the left side front cover.
(2) Pull the lower part of the left side front cover
in front , lift it above, and remove the lower
part of the left side front cover.
Remove the screws use the supplied screwdriver.
2
Shift the flushing unit to the left.
(1) Remove the clasp.
(2) Hold The Handle And Shift The Flushing
Unit.
3
Clean the part of the sensor with a clean
stick.
4
Return the flushing unit to the original
position.
(1) Hold The Handle And Shift The Flushing
Unit.
(2) Fasten the clasp.
Tools required for cleaning
Clean stick (SPC-0527) Gloves
Goggles
Be sure to wear the attached goggles and gloves
when cleaning the area around the ink
head.Otherwise, you may get ink in your eyes.
The ink contains organic solvent.If you get the ink
on your skin or in your eyes, wash it away with
plenty of water immediately.
Screw
Lower part of the
left side front cover
Handle
clasp
Sensor
Handle
clasp

Table of Contents