3-15
Chapter 3 Setup
3
2
2
Setting Interval wiping
When a set time has elapsed, the machine automatically
wipes the nozzle surfaces of the head to remove any ink
droplets attached to the surfaces.
In case that deflection, nozzle missing, or symptom which
ink droplets fall down occurred, set the interval between
each operation shorter.
1
Press the
(MENU)
key in
Local.
2
Press to select SETUP 1 to 4, and
press the key.
Setup menu appears.
3
Press the
(>>) twice
.
4
Press to select “Interval Wiping”
, and press the key.
5
Press to set intervals.
Set Value : 3 to 255 min, OFF
When [OFF] is set, periodical wiping is not
executed.
6
Press the key.
7
Press the key several times to
end the setting.
Setting Head Gap
Set the head gap (height from the media to the nozzle
plane of the heads).
1
Press the
(MENU)
key in
Local.
2
Press to select SETUP 1 to 4, and
press the key.
Setup menu appears.
3
Press the (<<).
4
Press to select “Head Gap” and
press the key.
5
Press to set a value of the head
gap and press the key.
Set value : 1.5 to 7.0mm
6
Press the key.
7
Press the key several times to
end the setting.
The color tone may change, depending on the
timing when periodic wiping is performed. Check
in advance that the color tone is not affected.
The color tone may change, depending on the
timing when periodic wiping is performed. Check
in advance that the color tone is not affected.