5-5
Troubles for which error messages are given on the LCD
5
In Case of Trouble
Message Solution
• Execute the carriage out of the station maintenance, and clean the cap.
• A case weight of 600 ml cartridge is not set. Set the case weight on “600
ml CARTRIDGE” of “MACHINE SET”.
• Enter weight of the cartridge on “CART WEIGHT” of “SET UP”.
• If ink remains, enter weight of the cartridge on “CART WEIGHT” of “SET
UP”.
• If ink does not remain, replace with a new cartridge.
• Check illuminance of the LED UV lamp.
If it is lower than the set value, replace the lamp.
• Writing of the setting of remaining amount of ink has failed.
Remove and set the cartridge again to rewrite. If the error does not disap-
pear, replace with a new cartridge.
• The cartridge weight is not entered.
Enter the weight of the cartridge.
• Fill up ink of the displayed color. ( P.4-29)
(Supported from the firmware ver.3.80.)
• The drawing data is being received or has been received.
Set the Remote mode and draw all the received data( P.2-9), or clear
the data ( P.3-10).
The “DT” on the upper-right hand corner means “DATA REMAIN”.
The display priority is low, and if another warning or error is displayed, the
second line displays another message. In that case, you can check
whether the data has been received by the DT display in the upper-right
hand corner.
(Supported from the firmware ver.4.10)