2-6
Test drawing
Make test drawing in the specified direction to check whether there is nozzle clogging or other drawing failures
(such as wearing or missing).
1
Press the key in the local mode.
2
Select the drawing direction by pressing the
or key, and press the key.
When nozzle recovery is not set, test drawing is started in the
selected direction.
SCAN DIR: Draws in the scan (widthwise) direction of the media.
FEED DIR: Draws in the feed (longwise) direction of the media.
3
When nozzle recovery is set, press the or key
to set ON/ OFF and then press the key.
This is available for F/W Ver.3.30 and later.
ON: Draws with nozzle recovery ON.
OFF: Draws with nozzle recover OFF.
4
Test drawing ends.
Y-bar evacuates from the table, and then the mode returns to the local.
5
Check result of drawing.
When the result is normal, finish the operation. ( P.2-9)
When the result is abnormal, execute head cleaning. ( P.2-8)
Check before starting