2. Safety instructions | 2.4 - Before operational startup | 13
2.4.9.2 Electrostatically sensitive components
This device contains electrostatically sensitive components. Therefore, po
tential equalization must be provided when working on the device (antistatic
protection).
2.4.9.3 Replacing fuses
The device does not have any replaceable fuse.
The load cell supply is protected against short circuit.
In case of loss of load cell supply, disconnect the device from the supply volt
age, find out the cause and eliminate it.
After a cool down time of approx. 3 minutes, the supply voltage can be
switched on again.