10. SPM | 10.4 - System data | 132
SPM address Data type R/W Function
D11 DINT R Current gross/net weight selected with X72
D14 DINT R Max. weight (max. capacity; FSD = Full Scale Deflection)
D23 DINT W Activity counter, test of communication with device
D24 DINT W Limit 1 on
D25 DINT W Limit 1 off
D26 DINT W Limit 2 on
D27 DINT W Limit 2 off
D28 DINT W Limit 3 on
D29 DINT W Limit 3 off
D30 UDINT W Analog output for "transparent" mode
D31 DINT W Write value to fixed tare memory (X118, X119)