Expansion Stages and System Capacity
Table 27: Average power requirements of terminals
Terminals Socket Output P [mW]
MiVoice 5360
31
DSI-AD2 interface 280
MiVoice 5361 DSI-AD2 interface 680
MiVoice 5370 DSI-AD2 interface 680
MiVoice 5380 DSI-AD2 interface 820
MiVoice 5370, MiVoice 5380 with
power supply unit
DSI-AD2 interface 0
Expansion key module MiVoice
M530
MiVoice 5370 110
Expansion key module MiVoice
M530
MiVoice 5380 120
Expansion key module MiVoice
M535
MiVoice 5370, MiVoice 5380
0
32
Radio unit without power supply
unit SB-4+
DSI-AD2 interface
1500
33
Radio unit without power supply
unit SB-8
2 DSI-AD2 interfaces
1350
34
Radio unit with power supply unit
SB-4+/SB-8
1 or 2 DSI-AD2 interfaces lt; 100
ISDN terminal BRI-S interface
approx. 500
35
31
Although no longer available, the phone is still supported.
32
An MiVoice M535 always requires a power supply unit
33
The value applies to radio units with hardware version "-2". The value for hardware version “-1” is 300 mW lower.
34
The value applies to each interface and to radio units with hardware version “-2”. The value per interface for radio units with
hardware version “-1” is 150 mW lower.
35
The value depends greatly on the terminal type.
Release 7.1
System Manual for Mitel SMB Controller 82