APPENDICES
Appendix 5 Method of replacing High Performance model QCPU with Universal model QCPU
App - 132
9
Parameters
10
Device Explanation
11
CPU Module Processing
Time
12
Procedure for Writing
Program to CPU ModuleAppendicesIndex
2) Subroutine program
• In the subroutine program, the data for outputting ASCII codes using a
fixed scan interrupt program (10ms) are set to work devices. Also, the flag
for activating the processing in the fixed scan interrupt program is turned
ON.
• Specify the following arguments for the subroutine program.
First argument Output string storage address (Input)
Second argument Output module start Y number (Input)
Figure App.9 Sample program
Data specified by the CALL(P)
arguments are saved.
Output string storage
address
Number of output strings
Output module start number
Devices used for the string
output processing of the
interrupt program I31 are
initialized.
Yn0 to Yn7 (ASCII code),
Yn8 (strobe signal), and Yn9
(in-execution flag) are all
turned OFF.
The flag to activate the string
output processing of the interrupt
program is turned ON.

Table of Contents

Other manuals for Mitsubishi Q02CPU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q02CPU and is the answer not in the manual?

Mitsubishi Q02CPU Specifications

General IconGeneral
BrandMitsubishi
ModelQ02CPU
CategoryController
LanguageEnglish

Related product manuals