EasyManua.ls Logo

MKN FKECOD615T - Temperature Standard Setting; Cooking Zone Humidity Standard Setting

MKN FKECOD615T
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the unit
30 Operating instructions
3.6.2 Temperature standard setting
The adjustment range for the cooking zone temperature depends on
the cooking mode.
Cooking mode Standard value
(°C)
Adjustment
range (°C)
Alteration
increments (°C)
Steaming 100 30 - 130 1
Combisteaming 150 30 - 250 1
Hot air 180 30 - 300 1
Regeneration 50 30 - 150 1
3.6.3 Cooking zone humidity standard setting
The setting range for the cooking zone humidity depends on the type
of cooking.
Type of
cooking
Standard value
(%)
Setting range
(%)
Change
increments (%)
Steaming 100 90 - 110 90 - 100 - 110
Combisteaming 90 20 - 100 20 - 40 - 70 - 90 -
100
Hot air 100 0 - 100 0 - 25 - 50 - 75 -
100
Regeneration 100 0 - 100 0 - 25 - 50 - 75 -
100
10013865-0ABBE-B