Troubleshooting
89Operating instructions
Fault
no.
Error message
displayed
Description Measure to be taken
715
717
External core
temperature
sensor is defect-
ive
The external core
temperature sensor in
the cooking zone is
deactivated.
Use the internal
core temperature
sensor.
Contact Customer
service.
710 Vapour sensor
defective
Vapour elimination is
now only controlled by
the software. This
results in higher water
consumption.
Contact Customer
service
Water pressure
too low
As permanent error
message
Open the water
valve
If the water valve is
not closed, contact
Customer service
Water pressure
too low
As sporadic error
message
Activate fewer sim-
ultaneous water
consumers in the
kitchen.
Contact Customer
service
No water in the
waste trap
The waste trap is not
filled with sufficient
water.
Open the water
valve
2 l Pour water into
the cooking zone
If the error message
persists, contact
Customer service
Unit restarted
after a power fail-
ure
If there was no power
failure in the kitchen, it
could be an operating
error. An example of
this would be
unintentional
switching on and off
during a running
cooking program.
Power failure < 1
minute
Confirm the power
failure message
Continue with the
cooking program
No cleaning neces-
sary
Power failure > 1
minute
Cooking program
cancelled
Perform cleaning
WaveClean can-
celled
Please observe the explanations and notes in
the chapter on "Automatic cleaning (Wave-
Clean)"
10013865-0ABBE-B