EasyManua.ls Logo

MKN FKECOD615T - Causes of Errors and Remedies (Part 2)

MKN FKECOD615T
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
89Operating instructions
Fault
no.
Error message
displayed
Description Measure to be taken
715
717
• External core
temperature
sensor is defect-
ive
The external core
temperature sensor in
the cooking zone is
deactivated.
• Use the internal
core temperature
sensor.
• Contact Customer
service.
710 • Vapour sensor
defective
Vapour elimination is
now only controlled by
the software. This
results in higher water
consumption.
• Contact Customer
service
• Water pressure
too low
As permanent error
message
• Open the water
valve
• If the water valve is
not closed, contact
Customer service
• Water pressure
too low
As sporadic error
message
• Activate fewer sim-
ultaneous water
consumers in the
kitchen.
• Contact Customer
service
• No water in the
waste trap
The waste trap is not
filled with sufficient
water.
• Open the water
valve
• 2 l Pour water into
the cooking zone
• If the error message
persists, contact
Customer service
• Unit restarted
after a power fail-
ure
If there was no power
failure in the kitchen, it
could be an operating
error. An example of
this would be
unintentional
switching on and off
during a running
cooking program.
• Power failure < 1
minute
• Confirm the power
failure message
• Continue with the
cooking program
• No cleaning neces-
sary
• Power failure > 1
minute
• Cooking program
cancelled
• Perform cleaning
• WaveClean can-
celled
• Please observe the explanations and notes in
the chapter on "Automatic cleaning (Wave-
Clean)"
10013865-0ABBE-B

Table of Contents