DIPLOMAT
8•208
Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Prior to the first start of the day perform a general inspection including oil
and coolant levels. Keep a maintenance log on number of hours in operation
since the last service. Perform any service or maintenance that may be due.
• People and animals must be clear of hazards of electrical
shock and moving parts.
Appliances and other large AC electrical loads are off.
Push and hold control switch in START position until the generator starts.
Release switch. On diesel models the control switch may flash up to 15
seconds, indicating engine preheat.
NOTE: Diesel models may require priming. Hold control
switch in OFF position for one minute. Repeat if necessary.
The diesel generator fuel pick-up tube is cut to approximately
1/4 tank so as not to run the main engine out of fuel.
WARNING: Excessive cranking can overheat and damage the
starter motor. Do not crank for more than 30 seconds at any
one time. Wait at least two minutes before resuming. If the
generator fails to start refer to the manufacturer’s manual.
WARNING: When the motorhome is parked, position the
dash air conditioner vent control in the OFF position to pre-
vent outside air from entering the motorhome. The engine
exhaust contains carbon monoxide, which is an odorless and
colorless gas. Carbon monoxide is poisonous and can cause
unconsciousness and/or death. Inspect the exhaust system
thoroughly before starting the generator. Do not block the
exhaust pipe or situate the motorhome where the exhaust may
accumulate either outside or inside the motorhome, or around
any nearby vehicles. Operate the generator only when safe dis-
persion of exhaust can be assured. Monitor the outside condi-
tions to be sure that the exhaust continues to disperse safely.
WARNING: When parking near high grass be sure that the
hot exhaust does not come into contact with the grass, it could
be a fire hazard.
Turn off the appliances and disconnect other AC loads being used. Allow the
generator to run unloaded for at least one minute before shutdown. This will
allow the engine to cool. Push and hold the control switch in the STOP position
until the generator stops. Release the switch.
NOTE: Diesel models require only a momentary stop signal.
Starting the
Generator
Prestart Checks
Stopping the
Generator