Chapter 8 Software Commands Gen 3 Site Controller System Manual
Site Controller Commands
8-10 68P80801E30-A 5/1/2002
DELOOP
Syntax:
deloop <line #>
The 'deloop' command takes any Tl /E1 line out of a Remote Loopback
mode. The line # argument can be any Tl/El line 1 - 4. To deloop all TI/El
lines, enter 0 for the line # argument.
Example:
PING BR
Syntax:
ping br
The purpose of this command is to check ethernet connectivity. This
command sends a ping message to all Base Radios connected to
ethernet and displays the cabinet and position number and the ethernet
address for BRs that respond successfully.
Cab/pos number and ethernet address will be displayed for BRs that respond
successfully:
Note: Quad BR must be switched to test mode, by performing diagnostic
reset (press reset button located on the BR front panel and follow on
screen instructions), in order to communicate with iSC. Refer to
System Testing section in Volume 1 (System Installation and
Testing) of EBTS manual for more information.
iSC>deloop 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola iDEN Site Controller and is the answer not in the manual?