68P80801E30-A 5/1/2002 8-9
Gen 3 Site Controller System Manual Chapter 8 Software Commands
Site Controller Commands
Example:
WHOIS ISC
Syntax:
whois isc
The 'whois isc' command displays the MAC addresses of the active and
standby site controller, and reports which site controller the user is
connected to.
Example:
LOOP
Syntax:
loop <line #>
The 'loop' command puts any TI /E1 line into a remote loopback mode. The
<line #> argument can be any Tl/El line 1 - 4. To put all TI/El lines into
loopback mode, enter 0 for the <line #> argument.
Example:
iSC> switch isc
switch iSC accomplished, please switch your service terminal to the newly
activated iSC to continue with your diagnostics.
iSC> whois isc
iSC active ethernet address 44:44:44:44:44:33
iSC standby ethernet address 00:00:00:00:00:00
You are connected to active iSC.
iSC>loop 1