MOTOTRBO Base Station/Repeater – EME ASSESSMENT: Compliance Boundary Description D-5
D.6 Compliance Boundary Description
Based on the analysis in section D.5, the compliance boundaries for occupational and general public
exposure are defined as cylinders enclosing the antenna (see Figure D-3.), extending 75 cm (one
wavelength) above and below the physical antenna, with radii:
Occupational exposure:
General Public exposure:
Figure D-3. Compliance boundary for general public (GP) and occupational (OCC) exposure
D.7 References
1. International Commission on Non-Ionizing Radiation Protection (ICNIRP), “Guideline for
Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields,” Health
Physics, vol. 74, no. 4, pp. 494-522, April 1998.
2. United States Federal Communication Commission, “Evaluating compliance with FCC
guidelines for human exposure to radio frequency electromagnetic fields,” OET Bulletin 65,
Ed. 97-01, Section 2 (Prediction Methods), August 1997.
3. US Code of Federal Regulations, Title 47, Volume 1, Sec. 1.1310 Radio frequency radiation
exposure limits (Revised as of October 1, 2003).
http://edocket.access.gpo.gov/cfr_2003/octqtr/47cfr1.1310.htm.
m
OCC
2.1
m
GP
6
OCCG
/