Troubleshooting 3-15
3.3.3 Troubleshooting Chart
Follow the procedures in the troubleshooting charts below to isolate the cause of PA problems.
Figure 3-9 Fan Troubleshooting Flow Chart (PA)
Note
1. PA fan supply should be measured at feed-through capacitor output.
HIGH PA TEMP
or PA FAN
FAILURE
Is PA
Fan On?
Check Fan
Supply
Voltage
1
Check Fan
Supply
Voltage
1
Replace Fan
if Needed
Unplug Fan
and
Remeasure
Supply
Voltage
1
Is V
>10V?
Is V
>10V?
Troubleshoot
Fan Switch
Replace Fan
if Needed
Yes
No
Yes
No
No
Yes
Is V
>10V?
Replace Fan
if Needed
No
Yes
Troubleshoot
Fan Switch