EasyManua.ls Logo

MTU 12V2000B26F - Engine Coolant - Level Check

MTU 12V2000B26F
147 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.12.2 Engine coolant – Level check
Preconditions
Engine is stopped and starting disabled.
MTU Fluids and Lubricants Specifications (A001061/..) are available.
WARNING
Coolant is hot and under pressure.
Risk of injury and scalding!
Let the engine cool down.
Wear protective clothing, gloves, and goggles / safety mask.
Checking coolant level at filler
neck:
1. Turn breather valve on coolant expansion
tank counterclockwise to the first stop and
allow pressure to escape.
2. Continue to turn breather valve counter-
clockwise and remove.
3. Check coolant level (coolant must be visi-
ble at the lower edge of the cast-in eye or
at the marking plate).
4. Top up with treated coolant as necessary
(→ Page 111).
5. Check and clean breather valve.
6. Place breather valve on filler neck and
close.
Coolant-level check by means of level sensor:
1. Switch on engine control system and check readings on the display.
2. Top up with treated coolant as necessary (→ Page 111).
108 | Task Description | MS150118/00E 2014-07
TIM-ID: 0000000037 - 004

Table of Contents

Related product manuals