EasyManuals Logo

MTU 12V2000B26F User Manual

MTU 12V2000B26F
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
4.6 Emergency stop
NOTICE
An emergency stop causes extreme stress to the engine plant.
Risk of overheating, damage to components!
Initiate emergency stop only in emergency situations.
Emergency stop
Item Action
Emergency stop pushbutton Press EMERGENCY STOP pushbutton.
Engine is stopped by disconnecting the power supply to the ECU;
Emergency air shutoff flaps close (if provided);
Signalization (e.g. by horn, beacon) is activated.
After emergency stop
Item Action
Switchgear cabinet, control
panel etc. (depending on
manufacturer)
Press pushbutton for alarm acknowledgment.
Audible and visual signalization stops.
Engine Manually open emergency air shutoff flaps (if provided).
Engine is ready for starting.
MS150118/00E 2014-07 | Operation | 61
TIM-ID: 0000002307 - 003