7.5.3 Fuel – Draining
Preconditions
Engine is stopped and starting disabled.
WARNING
Fuels are combustible.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Fuel – Draining
1. Provide a suitable container in which to collect the fuel.
2. Remove fuel filter (→ Page 87).
3. Catch fuel as it runs out.
4. Install fuel filter (→ Page 87).
86 | Task Description | MS150118/00E 2014-07