7.15.2 Differential pressure gauge – Check
WARNING
Fuels are combustible.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Differential pressure gauge – Check
1. Switch on fuel treatment system (optional).
2. Set the alarm points at the differential pressure gauge to zero.
Result: Alarm is issued after preset delay.
3. Reset the alarm points at the differential pressure gauge to the specified values.
MS150118/00E 2014-07 | Task Description | 123