Inclined positions, standard oil system (reference: waterline)
Number of cylinders 12 16 18
Longitudinal inclination, continu-
ous max. driving end bottom (op-
tion: max. operating inclination po-
sitions)
L Degrees (°) 5 5 5
Longitudinal inclination, continu-
ous max. driving end top (option:
max. operating inclination posi-
tions)
L Degrees (°) 5 5 5
Transverse inclination continuous
max. (design: max. operating incli-
nation positions)
L Degrees (°) 10 10 10
Table 29: Inclined positions, standard oil system (reference: waterline)
Capacities
Number of cylinders 12 16 18
Engine coolant capacity, engine
side (without cooling system)
R Liters 63 70 73
Charge-air coolant, engine side R Liters - - -
Fuel, engine side R Liters 6 6 7
Engine oil capacity, initial filling
(standard oil system) (design: max.
operating inclination positions)
R Liters 92 114 122
Oil change quantity max. (standard
oil system) (design: max. operating
inclination positions)
R Liters 80 102 110
Table 30: Capacities
Fan / fan cooler
Number of cylinders 12 16 18
Fan, pusher type X X X
Fan drive: mechanical via V-belt X X X
Table 31: Fan / fan cooler
Sound
Number of cylinders 12 16 18
Exhaust noise, not attenuated - DL
(free-field sound pressure level Lp,
1 m distance, ISO 6798, +3 dB(A)
tolerance)
R dB(A) 112 - 115
Exhaust noise, not attenuated - DL
(sound power level LW, ISO 6798,
+3 dB(A) tolerance)
R dB(A) 125 - 127