EasyManua.ls Logo

MTU 12V2000B26F - Page 34

MTU 12V2000B26F
147 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inclined positions, standard oil system (reference: waterline)
Number of cylinders 12 16 18
Longitudinal inclination, continu-
ous max. driving end bottom (op-
tion: max. operating inclination po-
sitions)
L Degrees (°) 5 5 5
Longitudinal inclination, continu-
ous max. driving end top (option:
max. operating inclination posi-
tions)
L Degrees (°) 5 5 5
Transverse inclination continuous
max. (design: max. operating incli-
nation positions)
L Degrees (°) 10 10 10
Table 44: Inclined positions, standard oil system (reference: waterline)
Capacities
Number of cylinders 12 16 18
Engine coolant capacity, engine
side (without cooling system)
R Liters 63 70 73
Charge-air coolant, engine side R Liters - - -
Fuel, engine side R Liters 6 6 7
Engine oil capacity, initial filling
(standard oil system) (design: max.
operating inclination positions)
R Liters 92 114 122
Oil change quantity max. (standard
oil system) (design: max. operating
inclination positions)
R Liters 80 102 110
Table 45: Capacities
Fan / fan cooler
Number of cylinders 12 16 18
Fan, pusher type X X X
Fan drive: mechanical via V-belt X X X
Table 46: Fan / fan cooler
Sound
Number of cylinders 12 16 18
Exhaust noise, not attenuated - DL
(free-field sound pressure level Lp,
1 m distance, ISO 6798, +3 dB(A)
tolerance)
R dB(A) 111 115 115
Exhaust noise, not attenuated - DL
(sound power level LW, ISO 6798,
+3 dB(A) tolerance)
R dB(A) 124 127 128
34 | Technical Data | MS150118/00E 2014-07
TIM-ID: 0000054519 - 001

Table of Contents

Related product manuals