Number of cylinders 12 16 18
Lube oil operating pressure before
engine, shutdown
L bar 4.0 4.0 4.0
Lube oil fine filter (main circuit):
number of cartridges per unit
2 3 3
Table 86: Lube oil system
Fuel system
Number of cylinders 12 16 18
Fuel pressure at engine supply
connection, min. (during engine
start)
L bar -0.5 -0.5 -0.5
Fuel pressure at engine supply
connection, max. (during engine
start)
L bar 0.5 0.5 0.5
Fuel supply flow rate, max. A Liters/min 30 30 30
Fuel return flow rate, max. A Liters/min 30 30 30
Table 87: Fuel system
General operating data
Number of cylinders 12 16 18
Coolant preheating: preheating
temperature (min.)
L °C 32 32 32
Starting is blocked if the engine
coolant temperature is below
°C -20 -20 -20
Firing speed, from R rpm 100 100 100
Firing speed. to R rpm 120 120 120
Table 88: General operating data
Inclined positions, standard oil system (reference: waterline)
Number of cylinders 12 16 18
Longitudinal inclination, continu-
ous max. driving end bottom (op-
tion: max. operating inclination po-
sitions)
L Degrees (°) 5 5 5
Longitudinal inclination, continu-
ous max. driving end top (option:
max. operating inclination posi-
tions)
L Degrees (°) 5 5 5
Transverse inclination continuous
max. (design: max. operating incli-
nation positions)
L Degrees (°) 10 10 10
Table 89: Inclined positions, standard oil system (reference: waterline)