EasyManua.ls Logo

NAPCO x255 - User Authority Level and Options; User Option Explanations

NAPCO x255
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
L NAPCO Security Systems
X GEM-X255 Programming Instructions
Page 11
WI1092E 10/05
Press U to save each code.
To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program
a new User Code as previously described. Press NEXT
P button to proceed.
Example: Program a code of “2222” for user 02, with User Option of “User Program”, User “Level 3” and Access Control Option
“Keypad No. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for access control option.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described
above and press
U to save. Similarly, to cancel a code, blank out each number of the code and press U to save to
save.
USER AUTHORITY LEVEL
FUNCTION LEVEL*
DISPLAY ZN FAULTS
1
DISPLAY ZN BYPASSED
1
DISPLAY ZN DIRECTORY
1
ACTIVATE BELL TEST
1
DISPLAY PHONE #’S
1
DISPLAY SYS TRBL
1
DISPLAY FIRE ALARM
1
DISPLAY FIRE TRBL
1
DISPLAY OP/CL
3
ACTIVATE OVERVIEW
3**
ACTIVATE CHIME
1
ACTIVATE WATCH
2
RESET SYSTEM TRBL
3
RESET SENSOR MSG
3
START EXIT TIME
1
FAULT FIND
***
ACTIVATE LOCATE
***
EZM ZONE FIND
***
ACTIVATE DIALER TEST
3
DISPLAY ALARM LOG
3
DISPLAY TOTAL LOG
3
DISPLAY FIRE LOG
3
DISPLAY OP/CL LOG
3
DISPLAY SYSTEM LOG
3
AUTOARM IN 1-4HRS
2
DISPLAY AUTOARM SCHD
3
ACTIVATE PROGRAM
3**
ACTIVATE DOWNLOAD
3
DISPLY RF XMITTER STAT
1
RELAY CONTROL
1
KEYPAD DISPLAY FUNCTION MENU
NOTES:
* Minimum Level required to access function
** Level-3 Code with appropriate user option
*** Requires Dealer Code
Related User Options: Ambush Code” (Address 0495), “Panel Access Code” (Address
0490), “Dealer Security Code” (Address 0500) & “Enable User Code by Area” (Address
2455-2550).
OPTIONS EXPLANATION
Disabled User Code not active in this area.
Blocked View Allows User Code to block another code from being viewed by another user.
An unblocked code cannot view a blocked code, but a blocked code can
view all codes. The master user code and the dealer program code can view
all codes.
User Program User Program Option is enabled for Keypad 1 only, wherever it is connected
(any area). If enabled, Level 3 must also be enabled.
Bypass Allows User Code to bypass zones.
Overview This option, along with Level 3 Authorization, enables selection of
OVERVIEW mode at a keypad. This Mode provides a system status display
of all areas at a glance.
Arm Only Prevents User Code from disarming this area.
Service A Service Code has restricted arm/disarm rights; if an area is armed with a
Service Code, a
5” appears on the GEM-RP1CAe2 keypad and the area can
be disarmed with any valid User Code, including a Service Code. If the area
is armed with OTHER than a Service Code, it CANNOT be disarmed with a
Service Code. This is typically used to allow tradesmen access to premises
under control of the owner.
Access This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When
the code is entered, the keypad will display “
ENTER NOW” and the Brown
Wire on the keypad will become Active Low (Ground Potential) for 7
seconds.
USER OPTIONS
Ambush
There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered
immediately prior to (and as part of) the regular User Code and (2) A separate
and unique User Code. Disarming with an Ambush Code will cause a silent
report to be sent to a central station. Thus, should a user be forced to disarm, he
can silently signal an emergency while appearing to be merely disarming the
system.
GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU

Table of Contents