X GEM-X255 Programming Instructions
L NAPCO Security Systems
Page 34
WI1092E 10/05
ZONE OPTIONS / ZONES 49-64 (ADDRESS 1802-1986)
ZONE OPTIONS / ZONES 49-64
ZONES 49 56
ZONES 57 64
ZONE OPTIONS ADDR Z49 Z50 Z51 Z52 Z53 Z54 Z55 Z56 ADDR Z57 Z58 Z59 Z60 Z61 Z62 Z63 Z64
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Priority 1802 1902
Priority with Bypass 1803 1903
Auto-Bypass 1804 1904
Selective Bypass 1805 1905
Keyswitch Arming 1806 1906
Auto-Bypass Re-entry 1807 1907
Pre-Alarm Warning 1808 1908
Never Arm 1809 1909
24-Hour Zone 1810 1910
Burg. Alarm Output 1811 1911
Pulsed Alarm Output 1812 1912
Fire Output (Lug E9) 1813 1913
Reset Relay 1814 1914
Auxiliary Relay 1815 1915
Entry/Exit 1 1816 1916
Entry/Exit 2 1817 1917
Exit/Entry Follower 1818 1918
Auto Reset 1819 1919
Swinger Shutdown 1820 1920
Chime 1821 1921
Abort Delay 1822 1922
Power-up Delay 1823 1923
Day Zone Open 1824 1924
Day Zone Short 1825 1925
Alarm on Day Zone 1826 1926
RPT Alarm Tel 1 1827 1927
RPT Alarm Restore Tel 1 1828 1928
RPT Trouble Tel 1 1829 1929
RPT Trouble Restore Tel 1 1830 1930
RPT Alarm Tel 3 1835 1935
RPT Alarm Restore Tel 3 1836 1936
RPT Trouble Tel 3 1837 1937
RPT Trouble Restore Tel 3 1838 1938
No EOL Resistor 1839 1939
Sensor Watch 1840 1940
Trouble on Open 1841 1941
Trouble on Short 1842 1942
Trouble on Night Open 1843 1943
Zone Area 1 1844 1944
Zone Area 2 1845 1945
Zone Area 3 1846 1946
Zone Area 4 1847 1947
Zone Area 5 1848 1948
Zone Area 6 1849 1949
Zone Area 7 1850
1950
Zone Area 8 1851
1951
Guard Tour Bypass 1853
1953
Zone ANDing Group 1 1854
1954
Zone ANDing Group 2 1855
1955
Zone ANDing Group 3 1856
1956
Zone ANDing Group 4 1857
1957
Zone ANDing Group 5 1858
1958
Zone ANDing Group 6 1859
1959
Zone ANDing Group 7 1860
1960
Zone ANDing Group 8 1861 1961
Interior #1 Bypass 1862 1962
Interior #2 Bypass 1863 1963
Keypad Sounder on Alarm 1864
1964
Fire (C) 1875 1975
Fire Alarm Verification (C) 1876
1976
Chime 2
1886 1986
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)).
Do not program if "K Series" keypads (with "
P" and "Q" buttons) are used in the system.
Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
Interior (STAY) Bypass 1884
1984
See Zone Options on Page 37.