L NAPCO Security Systems
X GEM-X255 Programming Instructions
Page 31
WI1092E 10/05
ZONES 1 8
ZONES 9 16
ZONE OPTIONS ADDR Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 ADDR Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
50ms Loop Response (A)
1200
20ms Loop Response (A)
1201
Priority 1202 1302
Priority with Bypass 1203 1303
Auto-Bypass 1204 1304
Selective Bypass 1205 1305
Keyswitch Arming 1206 1306
Auto-Bypass Re-entry 1207 1307
Pre-Alarm Warning 1208 1308
Never Arm 1209 1309
24-Hour Zone 1210 1310
Burg. Alarm Output 1211 1311
Pulsed Alarm Output 1212 1312
Fire Output (Lug E9) 1213 1313
Reset Relay 1214 1314
Auxiliary Relay 1215 1315
Entry/Exit 1 1216 1316
Entry/Exit 2 1217 1317
Exit/Entry Follower 1218 1318
Auto Reset 1219 1319
Swinger Shutdown 1220 1320
Chime 1221 1321
Abort Delay 1222 1322
Power-up Delay 1223 1323
Day Zone Open 1224 1324
Day Zone Short 1225 1325
Alarm on Day Zone 1226 1326
RPT Alarm Tel 1 1227 1327
RPT Alarm Restore Tel 1 1228 1328
RPT Trouble Tel 1 1229 1329
RPT Trouble Restore Tel 1 1230 1330
RPT Alarm Tel 3 1235 1335
RPT Alarm Restore Tel 3 1236 1336
RPT Trouble Tel 3 1237 1337
RPT Trouble Restore Tel 3 1238 1338
No EOL Resistor 1239 1339
Sensor Watch 1240 1340
Trouble on Open 1241 1341
Trouble on Short 1242 1342
Trouble on Night Open 1243 1343
Zone Area 1 1244 1344
Zone Area 2 1245 1345
Zone Area 3 1246 1346
Zone Area 4 1247 1347
Zone Area 5 1248 1348
Zone Area 6 1249 1349
Zone Area 7 1250
1350
Zone Area 8 1251
1351
2-Wire Smoke Detectors (B) 1252
Guard Tour Bypass 1253
1353
Zone ANDing Group 1 1254
1354
Zone ANDing Group 2 1255
1355
Zone ANDing Group 3 1256
1356
Zone ANDing Group 4 1257
1357
Zone ANDing Group 5 1258
1358
Zone ANDing Group 6 1259
1359
Zone ANDing Group 7 1260 1360
Zone ANDing Group 8 1261 1361
Interior #1 Bypass 1262 1362
Interior #2 Bypass 1263
1363
Keypad Sounder on Alarm 1264 1364
Fire (C) 1275
1375
Fire Alarm Verification (C) 1276
1376
Chime 2
1286 1386
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)). Zone Area 1
is enabled for the first 8 zones only, by default.
Do not program if "K Series" keypads (with "
P" and "Q" buttons) are used in the system.
Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).
Interior (STAY) Bypass 1284
1384
ZONE OPTIONS / ZONES 1-16 (ADDRESS 1200-1386)
ZONE OPTIONS / ZONES 1-16
See Zone Options on Page 37.