Appendix B: Feature Kits B-25
7453-K641
Serial Modem for 7194 Printer
With this kit the 7194 printer can be placed in a remote location, away
from the terminal. The section provides details for installing this kit.
16292a
7194
2 Twisted-Pair
In-House Wiring
RS-232 Short Range Modem
006-8602085
RS-232 Extender Cable
497-0411815 - 4 m
1416-C417-0040
(9F/25F)
RS-232 Extender Cable
497-0411815 - 4 m
1416-C417-0040
(925/9F)
Installation Procedures
1. Install in-house wiring between the locations desired for the
terminal and the printer. The ends of the cable should be within 3
meters (10 feet) of the devices for the drop cables to reach.
Note: Use CAT 1 two-twisted pair 24 AWG communications cable
or equivalent.
2. Connect a serial modem to each end of the in-house wiring,
connecting RCV+ and RCV- on one end, and XMT+ and XMT- on
the other end, respectively, using one twisted pair for RCV and
another twisted pair for XMT.
3. For the printers, connect one end of the 497-0411815 drop cable to a
9-pin RS-232 port on the terminal. Connect the other end to the
serial modem via the 25-pin āDā shell connector, securing it with
the thumbscrews.