Hardware Installation 2-67
RPSL
By default, the RPSL open/close sense setting is Normally Closed. RPSL printer-cash
drawer polarity settings can be configured in either of two ways:
through the FitClient LE utility
through the config.xml settings
JavaPOS
Configuring through FitClientLEutility
To change the sense settings in the FitClientLEutility, configure the value of the
following parameters.
Normally Open
Switch Polarity
Normally Closed
Switch Polarity
(Default)
Parameter Name Parameter Value Parameter Value
Printer Cash Drawer
Invert CashDrawer
Status
True False
Configuring through config.xml settings
To change the sense settings in config.xml, go to
/usr/local/NCRRetail/jpos/res/config.xml and configure the following registry
values.
Normally Open
Switch Polarity
Normally Closed
Switch Polarity
(Default)
Registry Name Value Value
Printer Cash Drawer
InvertCDPolarity T F