Loading...
Program 20 : System Option Setup
20-19 : System Options for Caller ID
Level
IN
Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID fea-
ture.
Input Data
Item No. Item Input Data Default Note
01 Caller ID Displaying Format
(if displaying digits are more than 12
digits)
0 = First 10 digits (Upper)
1 = Last 10 digits (Lower)
0
02 Caller ID Wait Timer
When an incoming CO call is received,
the SL1000 starts the timer. It will wait
the programmed time for Caller ID infor-
mation from Telco before connecting the
CO call.
0 ~ 30 seconds 5
03 Caller ID Edit Mode
If Caller ID Edit Mode is disabled (0), no
trunk access code will be added to the
Caller ID. If this option is enabled (1), the
trunk access code entered in Program
10-02-05 will be added to the beginning
of the Caller ID.
0=Off
1=On
0
04 Wait Facility IE Timer
This timer is used with ISDN trunks to
determine how long the system waits for
the Caller ID name from the Telco.
0 ~ 64800 seconds 10
05 Caller ID Sender Queuing Time
(Sender Wait)
0 ~ 64800 seconds 0
07 Long Distance Code Up to two digits No setting
08 Area Code Up to six digits No setting
Conditions
None
Feature Cross Reference
Caller ID
ISSUE 1.1SL1000
Program
20
Program 20 : System Option Setup2-182