Program 80 : Basic Hardware Setup for System
80-12 : Caller ID Receiver Setup
Level
IN
Description
Use Program 80-12 : Caller ID Receiver Setup defines the type and level for Caller ID detection of
DSP.
Input Data
Item No. Item Input Data Default Note
01 Type 0 = NTT
1 = Other
2 = Korea
1 (V1.5 Changed)
02 Level (Mark) 0 ~ 32766 50 (V1.5 Added)
03 Level (Space) 0 ~ 32766 50 (V1.5 Added)
04 Bit Sampling Type 0 = Other
1 = Malaysia
0 (V1.5 Added)
05 1st Bit Offset 0 ~ 32766 10 (V1.5 Added)
06 Minimum Seizure Count 0 ~ 32766 10 (V1.5 Added)
07 Guard Time when Mark 0 ~ 32766 1 (V1.5 Added)
Conditions