Program 80 : Basic Hardware Setup for System
80-08 : MFC Tone Setup
Level
IN
Description
Use Program 80-08 : MFC Tone Setup to define the duration (On time) and pause (Off time) for MFC
dialing. This option affects all trunk line calls system wide. And also it is possible to adjust the level of
tone.
Input Data
Item No. Item Input Data Default
01 Duration (On time) 1 ~ 255 (20 ms ~ 5100 ms) 5 (100 ms)
02 Pause (Off time) 1 ~ 255 (20 ms ~ 5100 ms) 5 (100 ms)
03 Tone Level 1~97(-45dB~+3dB) 77(-7dB)
Duration
Pause
Conditions
None
Feature Cross Reference
None