Program 90 : Maintenance Program
90-02 : Programming Password Setup
Level
IN
Description
Use Program 90-02 : Programming Password Setup to set the system passwords. For password
entry, the system allows eight users to be defined. Each user can have a:
• Unique alphanumeric name (up to 10 alphanumeric characters)
• Password entry of up to eight digits (using0~9,#and
*
)
• Password level
The IN level password is used by the System Installer for system programming. The SA or SB level
password cannot access the IN level programs. The reverse type (white on black) just beneath the De-
scription heading is the program access level. You can only use the program if your access level meets
or exceeds the level the program requires. (SA level password can access to SA or SB programs, and
SB level password can access to SB programs only.)
It is NOT recommended to change these data. If you must change these D ata
make sure you keep the ID/Password or you will never be able to enter the pro-
gram unless you clear all the System Data/Setting.
Input Data
User Number 1 ~ 8
Item No. Item Input Data
01 User Name Maximum 10 characters
02 Password Up to eight digits
03 User Level 0 = Prohibited User
2 = IN (Installer Level)
3 = SA (System Administrator Level 1)
4 = SB (System Administrator Level 2)
5 = UA (User Programming Administer Mode Level 1)
Default
User No. User Name Password Level Level Description
1 nec-i
******
1 (MF) Manufacture Level - Access to all system
program
2 tech 12345678 2 (IN) Installer Level - Access to all IN level
programs.
3 admin1 0000 3 (SA) System Administrator Level1-Re-
stricted Access
4 admin2 9999 4 (SB) System Administrator Level 2 - More Re-
stricted Access
5 user1 1111 5 (UA) User Programming Administer Mode
Level 1
Conditions
• More than one extension can be in the programming mode.
ISSUE 1.1 SL1000
Program
90
Programming Manual 2-489