Program 82 : Basic Hardware Setup for
Extension
82-01 : Incoming Ring Tone
Level
IN
Description
Use Program 82-01 : Incoming Ring Tone to set the incoming ring tones, which are the tones a user
hears when a call rings an extension. These tones are grouped into four ring tone Ranges (1 ~ 4), also
called patterns, that consist of a combination of frequencies. (You assign a specific Range to trunks in
Program 22-03 and to extensions in Program 15-02.) Within each range there are three frequency
Types : High, Middle and Low. (Service Code 820 allows users to choose the Type for their incoming
calls.) Each Type in turn consists of two frequencies and the modulation played simultaneously to
make up the tone. These frequencies are determined by their Frequency Number selected in Items 1
and 2 (see below). In this program, you assign the two Frequency Numbers and Modulation for each
Type, for each of the four Ranges. The chart below shows the default Frequency Numbers for each
Type in each Range.
Input Data
Incoming Ringing Tone Number 1 = Pattern 1 (Trunk Incoming)
2 = Pattern 2 (Trunk Incoming)
3 = Pattern 3 (Trunk Incoming)
4 = Pattern 4 (Trunk Incoming)
5 = Intercom Incoming Pattern
6 = Alarm Sensor Tone Pattern
Ringing Tone Type Number 1 = High
2=Mid
3 = Low
Item No. Item Input Data
01 Frequency 1
1 = 520 Hz
2 = 540 Hz
3 = 660 Hz
4 = 760 Hz
5 = 1100 Hz
6 = 1400 Hz
7 = 2000 Hz
02 Frequency 2
03 Modulation
0 = No Modulation
1=8HzModulation
2 = 16 Hz Modulation
3 = Envelope
Default
Incoming Ringing
Tone Number
Tone Type Frequency 1 (Hz) Frequency 2 (Hz) Modulation
Pattern 1
(Trunk Incoming)
High
Mid
Low
1100 Hz
660 Hz
520 Hz
1400 Hz
760 Hz
660 Hz
16 Hz Modulation
16 Hz Modulation
16 Hz Modulation
Pattern 2
(Trunk Incoming)
High
Mid
Low
1100 Hz
660 Hz
520 Hz
1400 Hz
760 Hz
660 Hz
8 Hz Modulation
8 Hz Modulation
8 Hz Modulation
Pattern 3
(Trunk Incoming)
High
Mid
Low
2000 Hz
1400 Hz
1100 Hz
760 Hz
660 Hz
540 Hz
16 Hz Modulation
16 Hz Modulation
16 Hz Modulation
ISSUE 1.1SL1000
Program
82
Program 82 : Basic Hardware Setup for Extension2-440